Fluke 787 Loop Calibrator Processmeter

OUR PRICE: Discontinued, replaced by Fluke 787B

Item Number: FLUKE-787

Manufacturer: FLUKE

Manufacturer Part No: FLUKE-787

Fluke 787

Fluke Model 787 Process Meter & Calibrator

The Fluke 787 ProcessMeter puts a complete troubleshooting solution in the palm of your hand.  Get in touch with more information, faster and easier with the newest member of the Fluke 80 Series, the  787 ProcessMeter. The 787 gives you the measurement capabilities you expect from our rugged, reliable DMMs plus the ability to source, simulate, or measure dc current with 1 microamp resolution and accuracy of 0.05%. Put it all together and you have the ideal tool for troubleshooting and calibrating current loop applications. So if youre tired of always tracking down a calibrator, lugging around two tools and switching back and forth, get the single best solution for doubling your power; The 787 ProcessMeter from Fluke. Features:

  • DMM and Loop Calibrator in One Tool
  • Precision 1000V, 440 mA digital multimeter
  • Measure AC/DC volts, AC/DC Current, Resistance, Continuity, and Frequency
  • 0.1% DC Voltage Accuracy
  • 0.05% DC current Accuracy, 1uA Resolution to 30 mA
  • Simultaneous mA and % of Scale Readout
  • True RMS AC voltage Measurement to 1 kHz
  • Frequency Measurement to 20 kHz
  • Min/Max/Average/TouchHold/Relative Modes
  • Diode Test and Continuity Beeper
  • DC Current Source/Loop Calibrator
  • 20 mA Current Source/Simulator
  • Simultaneous mA and % of Scale Readout
  • Manual Step (25%, Coarse, Fine) plus Auto Step and Auto Ramp
  • Clear LCD with Backlight; 4,000 Counts (30,000 counts for DC Current)
  • Externally Accessible Battery
  • 1000V Overload Protection on V, Ohms, Frequency
  • 150V Overload Protection on mA, Backed-up by 440 mA 1000V Fuse
  • Designed to Meet 1000 Volt IEC 1010 Cat III Standards

Technical Specifications:

DC Current Output:
(Battery operation)
Drive Capability:
0.000 to 20.000 mA or 4.000 to 20.000 mA
Over-Range to 24.000 mA
12 V Compliance, or 500 Ohms @ 20 mA
DC Current Simulate:
(External Loop Supply):
Drive Capability:
0.000 to 20.000 mA or 4.000 to 20.000 mA
Over-Range to 24.000 mA
1000 Ohms @20 mA; +/-0.05% Span
Adjustment Modes: Manual: Coarse Fine: 25% Step
Automatic: Slow Ramp, Fast Ramp, 25% Step
VDC: Ranges: 400.0 mV, 4.000V, 40.00V, 400.0V, 1000V
Accuracy: 0.1% Rdg + 1 Count
VAC (TRMS) to 1 kHz*: 400.0 mV, 4.000V, 40.00V, 400.0V, 1000V
Accuracy: 0.7% Rdg + 2 Counts
mA DC: 30.000 mA; +/-0.05% Rdg + 2 Counts
A DC: 1.000 A (0.440 A continuous); 0.2% Rdg + 2 Cts
A AC: 1.000 A (0.440 A continuous); 1% Rdg + 2 Cts
Resistance: 400 Ohm, 4.000 K-Ohm, 40.00 K-Ohm, 400.0 K-Ohm,
4.000 M-Ohm, 40.00 M-Ohm; +/-0.2% Rdg + 1 Cts
Frequency: 199.99 Hz, 1999.9 Hz, 19.999 kHz, 199.99 kHz
Accuracy: +/-0.005% + 1 Count
Diode Test: 2.400 V (Measures Diode Voltage Drop); +/-2%
Continuity: Beeps for Resistance < 100 Ohm
Maximum Protection: 1000 Vrms
Storage Temperature: -40 to 60 Deg C
Operating Temperature: -20 Deg C to 55 Deg C
Temperature Coefficient: 0.05 x (Specified Accuracy) per Deg C
Relative Humidity: 95% up to 30 Deg C; 75% up to 40 Deg C;
45% up to 50 Deg C; 35% Up to 55 Deg C
Vibration: Random, 2g, 5-500 Hz
Shock: 1 Meter Drop Test
Safety: Designed in Accordance with IEC 1010-1,
ANSI/ISA S82.01-1994
CAN/CSA C22.2 No. 1010.1-92
Overvoltage Category III
Size: 1.25" H x 3.41" W x 7.35"L
Weight: With Holster and Flex-Stand 638 g (22.5 oz)
Battery: Single 9V Alkaline Battery
Battery Life: 50 Hours Typical (Measurement)
12 Hours Typical (Sourcing 12 mA)
Warranty: 3 Years

Related Products

Hard Instrument Carry Case

Hard Instrument Carry Case

Hard Instrument Carry Case

Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details

Fluke C50

Fluke TL220

Fluke PV350 Pressure & Vacuum Module

morenothenex.blogspot.com

Source: http://www.calibratordepot.com/fluke-787-loop-calibrator-processmeter.aspx

0 Response to "Fluke 787 How to Measure Continuity"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel