- Accessories
- Frequency Calibrators
- Hart Communicators
- Humidity Measurement
- mA Loop/DC Calibrators
- Multifunction Calibrators
- Multimeters
- pH & ORP
- Pressure Calibrators & Pumps
- RTD Calibrators
- Temperature Baths & Dry Block Calibrators
- Thermocouple Calibrators
- Thermometers
- Calibration Service, Test Instrument Repair
- Vendor Marketplace
- Discontinued Products
- Ametek (Jofra) Products
- Ashcroft
- Druck & SI Pressure (GE Sensing)
- Extech Instruments
- Fluke & Hart Scientific
- GMC Instruments
- Martel Beta Calibrators
- Meriam Instruments
- Oakton
- Reed
- Techne
- Tek Know
- Vaisala
| | Fluke 787 Loop Calibrator Processmeter OUR PRICE: Discontinued, replaced by Fluke 787B Item Number: FLUKE-787 Manufacturer: FLUKE Manufacturer Part No: FLUKE-787 | | Fluke Model 787 Process Meter & Calibrator The Fluke 787 ProcessMeter puts a complete troubleshooting solution in the palm of your hand. Get in touch with more information, faster and easier with the newest member of the Fluke 80 Series, the 787 ProcessMeter. The 787 gives you the measurement capabilities you expect from our rugged, reliable DMMs plus the ability to source, simulate, or measure dc current with 1 microamp resolution and accuracy of 0.05%. Put it all together and you have the ideal tool for troubleshooting and calibrating current loop applications. So if youre tired of always tracking down a calibrator, lugging around two tools and switching back and forth, get the single best solution for doubling your power; The 787 ProcessMeter from Fluke. Features: - DMM and Loop Calibrator in One Tool
- Precision 1000V, 440 mA digital multimeter
- Measure AC/DC volts, AC/DC Current, Resistance, Continuity, and Frequency
- 0.1% DC Voltage Accuracy
- 0.05% DC current Accuracy, 1uA Resolution to 30 mA
- Simultaneous mA and % of Scale Readout
- True RMS AC voltage Measurement to 1 kHz
- Frequency Measurement to 20 kHz
- Min/Max/Average/TouchHold/Relative Modes
- Diode Test and Continuity Beeper
- DC Current Source/Loop Calibrator
- 20 mA Current Source/Simulator
- Simultaneous mA and % of Scale Readout
- Manual Step (25%, Coarse, Fine) plus Auto Step and Auto Ramp
- Clear LCD with Backlight; 4,000 Counts (30,000 counts for DC Current)
- Externally Accessible Battery
- 1000V Overload Protection on V, Ohms, Frequency
- 150V Overload Protection on mA, Backed-up by 440 mA 1000V Fuse
- Designed to Meet 1000 Volt IEC 1010 Cat III Standards
Technical Specifications: DC Current Output: (Battery operation) Drive Capability: | 0.000 to 20.000 mA or 4.000 to 20.000 mA Over-Range to 24.000 mA 12 V Compliance, or 500 Ohms @ 20 mA | DC Current Simulate: (External Loop Supply): Drive Capability: | 0.000 to 20.000 mA or 4.000 to 20.000 mA Over-Range to 24.000 mA 1000 Ohms @20 mA; +/-0.05% Span | Adjustment Modes: | Manual: Coarse Fine: 25% Step Automatic: Slow Ramp, Fast Ramp, 25% Step | VDC: | Ranges: 400.0 mV, 4.000V, 40.00V, 400.0V, 1000V Accuracy: 0.1% Rdg + 1 Count | VAC (TRMS) to 1 kHz*: | 400.0 mV, 4.000V, 40.00V, 400.0V, 1000V Accuracy: 0.7% Rdg + 2 Counts | mA DC: | 30.000 mA; +/-0.05% Rdg + 2 Counts | A DC: | 1.000 A (0.440 A continuous); 0.2% Rdg + 2 Cts | A AC: | 1.000 A (0.440 A continuous); 1% Rdg + 2 Cts | Resistance: | 400 Ohm, 4.000 K-Ohm, 40.00 K-Ohm, 400.0 K-Ohm, 4.000 M-Ohm, 40.00 M-Ohm; +/-0.2% Rdg + 1 Cts | Frequency: | 199.99 Hz, 1999.9 Hz, 19.999 kHz, 199.99 kHz Accuracy: +/-0.005% + 1 Count | Diode Test: | 2.400 V (Measures Diode Voltage Drop); +/-2% | Continuity: | Beeps for Resistance < 100 Ohm | Maximum Protection: | 1000 Vrms | Storage Temperature: | -40 to 60 Deg C | Operating Temperature: | -20 Deg C to 55 Deg C | Temperature Coefficient: | 0.05 x (Specified Accuracy) per Deg C | Relative Humidity: | 95% up to 30 Deg C; 75% up to 40 Deg C; 45% up to 50 Deg C; 35% Up to 55 Deg C | Vibration: | Random, 2g, 5-500 Hz | Shock: | 1 Meter Drop Test | Safety: | Designed in Accordance with IEC 1010-1, ANSI/ISA S82.01-1994 CAN/CSA C22.2 No. 1010.1-92 Overvoltage Category III | Size: | 1.25" H x 3.41" W x 7.35"L | Weight: | With Holster and Flex-Stand 638 g (22.5 oz) | Battery: | Single 9V Alkaline Battery | Battery Life: | 50 Hours Typical (Measurement) 12 Hours Typical (Sourcing 12 mA) | Warranty: | 3 Years | | Hard Instrument Carry Case Hard Instrument Carry Case with Pluck Foam to fit your instruments. 100's of sizes & styles available. Call for Details | | | | | |
0 Response to "Fluke 787 How to Measure Continuity"